Nervus

NEURO-IOM-32/B

System for Intraoperative Neurophysiological Monitoring with Advanced Functionality

  • enhanced SEP acquisition
  • enhanced MEP acquisition with a switching function and a wide range of stimulation parameters
  • 64 inputs (32 bipolar channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • transcranial electrical stimulator — up to 1000 V
  • Flexible configurations to ensure any monitoring needs

DESCRIPTION

Neuro-IOM is a multifunctional modular platform solution for intraoperative neurophysiological monitoring (IONM). Its application allows the surgical team to be informed about possible damage of nerve tissues resulting from surgeon actions and, thus, to prevent neurological deficit.

In most countries, intraoperative neurophysiological monitoring is a must for different types of surgery, such as spine surgery, brain surgery, brainstem surgery, etc. For spine surgery (for example, for scoliosis), the tactics are determined directly during IONM.

Neuro-IOM is our system for intraoperative neurophysiological monitoring. The extensive experience in developing and manufacturing neurophysiological equipment helped the Neurosoft company to enter the IONM market quickly several years ago. The system was registered and the company obtained the CE mark to sell the system in European countries. Meanwhile, more than a hundred Neuro-IOM systems are successfully used in hospitals and other healthcare facilities in Russia, Brazil, France, Jordan, Turkey, Bulgaria and other countries

Comprehensive solution for effective intraoperative neurophysiological monitoring

The standard configuration of Neuro-IOM (version 2) is the best solution for any type of neurological surgery. 32-channel amplifier and 4-channel transcranial electrical stimulator (up to 1000 V) with a wide range of pulse waveforms ensure the control of conduction pathways using motor evoked potentials even in the most complicated cases. 

Main features:

  • 64 amplifier inputs (32 bipolar channels);
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 12 channels for electrical stimulation;
  • 2 channels for direct nerve stimulation;
  • 4 channels for transcranial electrical stimulation;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.

The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes, a PC and the software are also included to the delivery set.

Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring

The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:

  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).

Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.

Transcranial electrostimulator (up to 1000 V), 12-channel electrostimulator, low-current stimulator, hearing and visual stimulators

Robust stimulators ensure high-quality responses during acquisition of brain evoked potentials and EMG exams.

The transcranial electrical stimulator deserves special attention. It is designed for stimulation of the motor cortex for recording motor evoked potentials of muscles. The stimulator allows single pulse and train stimulation as well as double train and train + pulse stimulation. Different types of stimulation can also be performed with the help of a built-in electronic switch.

Flexible configurations to ensure any monitoring needs

The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.

You can change and save the settings of any operation template at any time. The system has a large number of separately adjustable channels and stimulators. The use of preset templates simplifies and speeds up the set-up of the system for operations. This is a unique option for such systems. There is no IONM system in the world that is so flexible.

Not all options are available in all regions.

The support of HL7 standard allows integrating all diagnostic Neurosoft systems into the information system of a healthcare facility. Transcranial electrostimulator (up to 1000 V), 12-channel electrostimulator, low-current stimulator, auditory and visual stimulators